Power Control - AMF - Futuro

 
 
 
 
 
 
  Special Features
 
Compact
 
MIMIC type of front fascia makes it easy to use, even for an unskilled person
 
Indications for DG Set start and Stop, and all faults (LLOP, HWT, O/S, O/L, AUTO LOAD CHANGEOVER, BATT. LOW, SFS and LFL)
 
REMOTE monitoring and control facility available (optional)
 
Connection of external Indicating Lamps and push buttons is possible with very simple wiring
 
Important user settable parameters on rear
 
ANNUNCIATION with flasher and buzzer both, including ACCEPT, RESET and TEST facility
 
Facility for connection of external HOOTER
 
Design facilities easy and quick installation
 
Total wireless interiors
 
Virtually MAINTENANCE FREE
 
Existing non-AMF panels (standard panel) can be easily converted into AMF panels using AMF-Futuro
 
First time with Semi Auto Mode of Operation
  Introduction
  The AMF-Futuro is a user friendly and futuristic "AUTO MAINS FAILURE SOLUTION". AMF-Futuro is designed using latest digital technology to achieve reliable and accurate START-STOP Operation of DG Set, AUTO LOAD CHANGEOVER from DG and MAINS and FAULT ANNUNCIATION for SAFETY of DG Set. AMF-Futuro is innovatively designed keeping user's point of view in fore-front there by achieving reduced number of components, major part of cost and time required for fabrication and testing are saved, thus making AMF-Futuro economical in comparison with the conventional type panels.
  Operation
  AMF Futuro works on terminal voltage of Battery i.e. 12V or 24V . It can be made to work in four modes viz. Auto, Semi Auto, Test and Manual. It senses all the three phases of mains supply individually and gives starting pulse to DG Set starter (Sart Solenoid) along with FUEL SOLENOID, when any one phase goes below the set limit (settable on rear, 300-400V).

Thus DG starts automatically when it develops its rated voltage (settable between 300V-400V) the DG Contactor (or any switching device provided) is switched on after preset time delay. So, the power is supplied to load from DG Set. During this period, if any fault on the Engine side or Over load occurs, the supply to load will trip and DG will be stopped automatically and fault is indicated by a flashing LED and buzzer. Fault is acknowledge by pressing ACCEPT push button. When fault is acknowledged the LED becomes steady and buzzer stops. After the fault is rectified the DG set can be started once again.

When mains supply resumes, the load is changed-over to mains, but the Engine stops only after IDLE TIME set (settable on rear). In MANUAL mode the whole operation is achieved by manual push buttons. in TEST mode of operation, the load changeover is automatic and Engine Start and Stop operations are manual.
  Technical Data
Supply Voltage
:
12 V/ 24 V
Annunciation      - 
Faults              :
... HWT
... LLOP
... O/S
... O/L
... Batt. Low
... Set Fail to Start
... Low Fuel Level
... Spare-1
... Spare-2
  Others             : ... Crank On
... Fuel On
... DG On
... Load on DG
... (R-Y-B) Mains On
... Load on Mains
... Mains Fail
... Auto/Test/Manual
Panel Control DG                      : ... Start/Stop
... Close/Trip
  Mains                 : ... Close/Trip
    Annunciation     : ... Accept
... Reset
... Test
... Emergency Stop
Parameters (Setting) Mains                 : ... Voltage - 300- 400 V
... P.Up Time 0.3 to 30 sec
... Trip Time 0.3 to 30sec
    Cranking            : ... On Time 0.1 to 15 sec
... Off Time 0.1 to 15 sec
    DG                      : ... Voltage 300 to 400V
... Time Delay 0.3 to 30 s
... Idle Time 0.3 to 3 Min
    Flasher              : ... Time 0.1 - 10 sec
Contacts Input                  : ... LOP NC-C-NO
... HWT C-NO
... O/S C-NO
... O/L C-NO
... LFL C-NO
... SP-1 C-NO
... SP-2 C-NO
    Output                : ... FSR 12V/24V - 6A
... SSR 12V/24V - 10A
... Mains Contactor C-NO
... DG Contactor C-NO
Single Input Mains                 : 3-PH With Neutral
    DG                      : 2-PH
    Load                   : 1-PH
    Battery               : 12V/24V
Mounting Panel Cutout      : 225mm(L) * 92mm (H)
    Depth                 : 210mm
  Types of Operations in Various Modes
         
 
Mode >>
Auto
Semi Auto
Test
Manual
DG Start
Automatic
Automatic
Manual
Manual
DG Stop
Automatic
Manual
Manual
Manual
DG CLOSE
Automatic
Manual
Automatic
Manual
DG TRIP
Automatic
Manual
Automatic
Manual
Mains Close
Automatic
Manual
Automatic
Manual
Mains Trip
Automatic
Automatic
Automatic
Manual
Fuel Solenoid
Automatic
ON
ON
ON